Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
filereference:output:buildings [2020/06/24 16:24] – enviadmin | filereference:output:buildings [2020/06/29 12:39] (current) – edited the outputs and inserted some descriptions enviadmin | ||
---|---|---|---|
Line 29: | Line 29: | ||
==== Static ==== | ==== Static ==== | ||
+ | |||
+ | The static dataset includes some information that does not change during the model run. The *.DAT-files contain some statistical information about the specific buildings, such as the surface and volume (Building List.DAT) and the facade orientation, | ||
+ | |||
+ | The *.EDX/EDT output files contain the following parameters: | ||
+ | |||
+ | |||
| |**Variable** |**Unit** |**Description** | | | |**Variable** |**Unit** |**Description** | | ||
- | | |Albedo of facade| - | | | + | | |Albedo of facade| - | Albedo of the facade, the proportion of the radiation that is reflected by the facade |
- | | |Transmission of facade| - | | | + | | |Transmission of facade| - | Transmission of the facade, fraction of shortwave radiation transmitted through the material |
- | | |Emissivity of facade | - | | | + | | |Emissivity of facade | - | Emissivity of the facade, emissivity for longwave thermal radiation |
- | | |View factor sky | - | | | + | | |View factor sky | - | Proportion of sky that can be seen by the facade element |
- | | |View factor soil | - | | | + | | |View factor soil | - | Proportion of soil that can be seen by the facade element |
- | | |View factor bldg| - | | | + | | |View factor bldg| - | Proportion of buildings that can be seen by the facade element |
- | | |View factor veg| - | | | + | | |View factor veg| - | Proportion of vegetation that can be seen by the facade element |
- | | |Building number | - | | | + | | |Building number | - | Building number of building |
- | | |Facade/ Roof Greening LAI | m³/ | + | | |Facade/ Roof Greening LAI | m³/ |
- | | |Facade/ Roof Greening Thickness | cm | | | + | | |Facade/ Roof Greening Thickness | cm | Thickness of Facade/Roof Greening that is applied to the element |
==== Dynamic ==== | ==== Dynamic ==== | ||
+ | The dynamic dataset includes some information that does change during the model run. It is divided into the different building elements and contains the following parameters. | ||
+ | |||
===Wall=== | ===Wall=== | ||
| |**Variable** |**Unit** |**Description** | | | |**Variable** |**Unit** |**Description** | | ||
- | | |Wall shading flag| - | | | + | | |Wall shading flag| - | Information whether your facade element receives direct radiation or not | |
- | | |Temperature Node 1/ outside | °C | | | + | | |Temperature Node 1/ outside | °C | Temperature of the material outside |
- | | |Temperature Node 2 | °C | | | + | | |Temperature Node 2 | °C | Temperature of the material at node 2 | |
- | | |Temperature Node 3 | °C | | | + | | |Temperature Node 3 | °C | Temperature of the material at node 3 | |
- | | |Temperature Node 4 | °C | + | | |Temperature Node 4 | °C |
- | | |Temperature Node 5 | °C | | | + | | |Temperature Node 5 | °C |
- | | |Temperature Node 6 | °C | | | + | | |Temperature Node 6 | °C |
- | | |Temperature Node 7/ inside | °C | + | | |Temperature Node 7/ inside | °C |
- | | |Longwave radiation emitted by facade | W/m² | | | + | | |Longwave radiation emitted by facade | W/m² | Amount of longwave radiation that gets emitted by the facade |
- | | |Wind Speed in front of facade | m/s | | | + | | |Wind Speed in front of facade | m/s | Wind speed, vector sum over all 3 axis| |
- | | |Air Temperature in front of facade| °C | | | + | | |Air Temperature in front of facade| °C | Potential air temperature in the atmosphere in front of the facade |
- | | |Shortwave radiation received at facade | W/m² | + | | |Shortwave radiation received at facade | W/m² |
- | | |Absorbed direct shortwave radiation | W/m² | + | | |Absorbed direct shortwave radiation | W/m² |
- | | |Incoming longwave radiation | W/m² | | | + | | |Incoming longwave radiation | W/m² | Amount of longwave radiation that hits the facade |
- | | |Reflected shortwave radiation facade | W/m² | + | | |Reflected shortwave radiation facade | W/m² |
- | | |Sensible Heat transmission coefficient outside| W/ | + | | |Sensible Heat transmission coefficient outside| W/ |
| |Longwave Energy Balance| W/m² | | | | |Longwave Energy Balance| W/m² | | | ||