 +The static dataset includes some information that does not change during the model run. The *.DAT-files contain some statistical information about the specific buildings, such as the surface and volume (Building List.DAT) and the facade orientation, element count, element surface, green element count and green surface count (Building Statistics.DAT).
 +
 +The *.EDX/EDT output files contain the following parameters:
 +
 +
 |  |**Variable** |**Unit** |**Description** | |  |**Variable** |**Unit** |**Description** |
-|  |Albedo of facade| - |  +|  |Albedo of facade| - | Albedo of the facade, the proportion of the radiation that is reflected by the facade 
-|  |Transmission of facade| -  |  +|  |Transmission of facade| -  | Transmission of the facade, fraction of shortwave radiation transmitted through the material 
-|  |Emissivity of facade | -  |  +|  |Emissivity of facade | -  | Emissivity of the facade, emissivity for longwave thermal radiation 
-|  |View factor sky | - |  +|  |View factor sky | - | Proportion of sky that can be seen by the facade element 
-|  |View factor soil | -  |  | +|  |View factor soil | -  | Proportion of soil that can be seen by the facade element  | 
-|  |View factor bldg| -  |  | +|  |View factor bldg| -  | Proportion of buildings that can be seen by the facade element  | 
-|  |View factor veg| - |  | +|  |View factor veg| - | Proportion of vegetation that can be seen by the facade element  | 
-|  |Building number | -  |  +|  |Building number | -  | Building number of building 
-|  |Facade/ Roof Greening LAI | m³/m³  | | +|  |Facade/ Roof Greening LAI | m³/m³ LAI of Facade/Roof Greening that is applied to the element 
-|  |Facade/ Roof Greening Thickness | cm  |  |+|  |Facade/ Roof Greening Thickness | cm  | Thickness of Facade/Roof Greening that is applied to the element |
  
  
  
 ==== Dynamic ==== ==== Dynamic ====
 +The dynamic dataset includes some information that does change during the model run. It is divided into the different building elements and contains the following parameters. 
 +
 ===Wall=== ===Wall===
  
 |  |**Variable** |**Unit** |**Description** | |  |**Variable** |**Unit** |**Description** |
-|  |Wall shading flag| - |  +|  |Wall shading flag| - | Information whether your facade element receives direct radiation or not 
-|  |Temperature Node 1/ outside | °C  |  +|  |Temperature Node 1/ outside | °C  | Temperature of the material outside 
-|  |Temperature Node 2 | °C  |  +|  |Temperature Node 2 | °C  | Temperature of the material at node 2 
-|  |Temperature Node 3 | °C  |  +|  |Temperature Node 3 | °C  | Temperature of the material at node 3 
-|  |Temperature Node 4 | °C   +|  |Temperature Node 4 | °C   Temperature of the material at node 4  | 
-|  |Temperature Node 5 | °C   | | +|  |Temperature Node 5 | °C   Temperature of the material at node 5  
-|  |Temperature Node 6 | °C   | | +|  |Temperature Node 6 | °C   Temperature of the material at node 6  
-|  |Temperature Node 7/ inside | °C    +|  |Temperature Node 7/ inside | °C   Temperature of the material inside 
-|  |Longwave radiation emitted by facade | W/m²  | | +|  |Longwave radiation emitted by facade | W/m²  | Amount of longwave radiation that gets emitted by the facade 
-|  |Wind Speed in front of facade | m/s |  +|  |Wind Speed in front of facade | m/s | Wind speed, vector sum over all 3 axis
-|  |Air Temperature in front of facade| °C |  +|  |Air Temperature in front of facade| °C | Potential air temperature in the atmosphere in front of the facade 
-|  |Shortwave radiation received at facade | W/m²    +|  |Shortwave radiation received at facade | W/m²   Total amount of shortwave radiation received at the facade 
-|  |Absorbed direct shortwave radiation | W/m²    +|  |Absorbed direct shortwave radiation | W/m²   Amount of direct shortwave radiation that gets absorbed by the facade 
-|  |Incoming longwave radiation | W/m²  |  +|  |Incoming longwave radiation | W/m²  | Amount of longwave radiation that hits the facade 
-|  |Reflected shortwave radiation facade | W/m²    +|  |Reflected shortwave radiation facade | W/m²   Amount of reflected shortwave radiation that hits the facade 
-|  |Sensible Heat transmission coefficient outside| W/m²K  |+|  |Sensible Heat transmission coefficient outside| W/m²K Sensible Heat transmission coefficient at the outside of the building |
 |  |Longwave Energy Balance| W/m² |  | |  |Longwave Energy Balance| W/m² |  |