This is an old revision of the document!


Output Files: Buildings data (_BLDG_)

*Work in Progress…*

Dimension Nr Variables Format
3D-Facade 10 (Static), 50 (Dynamic) Binary (EDX/EDT)

Building Data

Contains the state of the 3D buildings both for static data like materials or view factors and dynamic variables such as facade temperature or heat fluxes. Data are stored in a 3D field with a data triple for X- , Y- and Z-Walls in each cell.

The Building data files are produced each main output interval (default: 60 min) and represent the general state of the building at the given model time. They are divided into static and dynamic data, the dynamic output is only written if a professional version of the software is used (not in LITE).

Variable list

This list represents the general variable structure. The actual sequence of the variables might differ but the same information is stored in total.

Static

Variable Unit Description
Albedo of facade -
Transmission of facade -
Emissivity of facade -
View factor sky -
View factor soil -
View factor bldg -
View factor veg -
Building number -
Facade/ Roof Greening LAI m³/m³
Facade/ Roof Greening Thickness cm

Dynamic

Wall

Variable Unit Description
Wall shading flag -
Temperature Node 1/ outside °C
Temperature Node 2 °C
Temperature Node 3 °C
Temperature Node 4 °C
Temperature Node 5 °C
Temperature Node 6 °C
Temperature Node 7/ inside °C
Longwave radiation emitted by facade W/m²
Wind Speed in front of facade m/s
Air Temperature in front of facade °C
Shortwave radiation received at facade W/m²
Absorbed direct shortwave radiation W/m²
Incoming longwave radiation W/m²
Reflected shortwave radiation facade W/m²
Sensible Heat transmission coefficient outside W/m²K
Longwave Energy Balance W/m²

Building

Variable Unit Description
Sum Humidity Flux at facade g/sm³
Temperature of building (inside) °C
Reflected shortwave radiation W/m²
Longwave radiation emitted W/m²

Greening

Variable Unit Description
Temperature Leafs °C
Air Temperature Canopy °C
Air Humidity Canopy g/kg
Longwave radiation emitted (two-side) W/m²
Wind Speed in front of greening m/s
Air Temperature in front of greening °C
Shortwave radiation received at greening W/m²
Incoming longwave radiation (two-side) W/m²
Reflected shortwave radiation W/m²
Transpiration Flux g/sm³
Stomata Resistance s/m
Water access factor -

Substrate

Variable Unit Description
Temperature Node 1/ outside °C
Temperature Node 2 °C
Temperature Node 3 °C
Temperature Node 4 °C
Temperature Node 5 °C
Temperature Node 6 °C
Temperature Node 7/ inside °C
Surface humidity g/kg
Humidity Flux at substrate g/sm³
Longwave radiation emitted by substrate W/m²
Wind Speed in front of substrate m/s
Air Temperature in front of substrate °C
Shortwave radiation received at substrate W/m²
Absorbed direct shortwave radiation W/m²
Incoming longwave radiation W/m²
Reflected shortwave radiation substrate W/m²
This website uses cookies. By using the website, you agree with storing cookies on your computer. Also you acknowledge that you have read and understand our Privacy Policy. If you do not agree leave the website.More information about cookies