This is an old revision of the document!
Output Files: Buildings data (_BLDG_)
*Work in Progress…*
Dimension | Nr Variables | Format |
---|---|---|
3D-Facade | 10 (Static), 50 (Dynamic) | Binary (EDX/EDT) |
Building Data
Contains the state of the 3D buildings both for static data like materials or view factors and dynamic variables such as facade temperature or heat fluxes. Data are stored in a 3D field with a data triple for X- , Y- and Z-Walls in each cell.
The Building data files are produced each main output interval (default: 60 min) and represent the general state of the building at the given model time. They are divided into static and dynamic data, the dynamic output is only written if a professional version of the software is used (not in LITE).
Variable list
This list represents the general variable structure. The actual sequence of the variables might differ but the same information is stored in total.
Static
Variable | Unit | Description | |
Albedo of facade | - | ||
Transmission of facade | - | ||
Emissivity of facade | - | ||
View factor sky | - | ||
View factor soil | - | ||
View factor bldg | - | ||
View factor veg | - | ||
Building number | - | ||
Facade/ Roof Greening LAI | m³/m³ | ||
Facade/ Roof Greening Thickness | cm |
Dynamic
Wall
Variable | Unit | Description | |
Wall shading flag | - | ||
Temperature Node 1/ outside | °C | ||
Temperature Node 2 | °C | ||
Temperature Node 3 | °C | ||
Temperature Node 4 | °C | ||
Temperature Node 5 | °C | ||
Temperature Node 6 | °C | ||
Temperature Node 7/ inside | °C | ||
Longwave radiation emitted by facade | W/m² | ||
Wind Speed in front of facade | m/s | ||
Air Temperature in front of facade | °C | ||
Shortwave radiation received at facade | W/m² | ||
Absorbed direct shortwave radiation | W/m² | ||
Incoming longwave radiation | W/m² | ||
Reflected shortwave radiation facade | W/m² | ||
Sensible Heat transmission coefficient outside | W/m²K | ||
Longwave Energy Balance | W/m² |
Building
Variable | Unit | Description | |
Sum Humidity Flux at facade | g/sm³ | ||
Temperature of building (inside) | °C | ||
Reflected shortwave radiation | W/m² | ||
Longwave radiation emitted | W/m² |
Greening
Variable | Unit | Description | |
Temperature Leafs | °C | ||
Air Temperature Canopy | °C | ||
Air Humidity Canopy | g/kg | ||
Longwave radiation emitted (two-side) | W/m² | ||
Wind Speed in front of greening | m/s | ||
Air Temperature in front of greening | °C | ||
Shortwave radiation received at greening | W/m² | ||
Incoming longwave radiation (two-side) | W/m² | ||
Reflected shortwave radiation | W/m² | ||
Transpiration Flux | g/sm³ | ||
Stomata Resistance | s/m | ||
Water access factor | - |
Substrate
Variable | Unit | Description | |
Temperature Node 1/ outside | °C | ||
Temperature Node 2 | °C | ||
Temperature Node 3 | °C | ||
Temperature Node 4 | °C | ||
Temperature Node 5 | °C | ||
Temperature Node 6 | °C | ||
Temperature Node 7/ inside | °C | ||
Surface humidity | g/kg | ||
Humidity Flux at substrate | g/sm³ | ||
Longwave radiation emitted by substrate | W/m² | ||
Wind Speed in front of substrate | m/s | ||
Air Temperature in front of substrate | °C | ||
Shortwave radiation received at substrate | W/m² | ||
Absorbed direct shortwave radiation | W/m² | ||
Incoming longwave radiation | W/m² | ||
Reflected shortwave radiation substrate | W/m² |